TT Club, the specialist international freight insurance provider is seeking greater emphasis on the critical dangers of toxic gas emissions associated with lithium-ion battery fires.  The failure of such batteries has the potential to occur with no prior warning, or with such speed that there is typically no time to react to any warning signs.

Devastating consequences of rapidly spreading, and often challenging to extinguish fires involving the batteries particularly in electric vehicles (EV) on board ships, and other parts of the supply chain have been well-documented in recent months.  There is however less awareness of the highly toxic combustion products that are released and their respective impact to the health and wellbeing of those exposed to the gases.

Based on the evidence of past fires the time between the initiation of a failed battery igniting to a discharge of toxic vapor can be measured in seconds rather than minutes. This is due to a process known as thermal runaway.  The rapid sequence of events typically occurs where an internal electrical short within one of the battery cells generates heat; this breaks down the internal structure of the battery, increasing the rate of the reaction in an ever-increasing cycle.  There is often a dramatic release of energy in the form of heat and a significant emission of toxic gases.

Potential vapor volume production
Source: Journal of Loss Prevention in the Process Industries 80 (2022)

The toxicity of gases given off from any given lithium-ion battery differ from that of a typical fire and can themselves vary but all remain either poisonous or combustible, or both.  They can feature high percentages of hydrogen, and compounds of hydrogen, including hydrogen fluoride, hydrogen chloride and hydrogen cyanide, as well as carbon monoxide, sulfur dioxide and methane among other dangerous chemicals.

In terms of hazards to the wellbeing of those in the vicinity of such an incident, one particularly problematic component is hydrogen fluoride (HF). Although HF is lighter than air and would disperse when released, a cloud of vapor and aerosol that is heavier than air may be formed (EPA 1993). On exposure to skin or by inhaling, HF can result in skin burns and lung damage that can take time (hours to weeks) to develop following exposure. HF will be quickly absorbed by the body via skin and lungs depleting vital calcium and magnesium levels in tissues, which can result in severe and possibly fatal systemic effects. The hydrogen content of the released gases can give rise to vapor cloud explosion risks which have the potential to cause significant damage.

TT advocates a range of measures to mitigate the risks. A prudent starting point would be to perform a fire risk assessment, considering the specific hazards presented by lithium-ion batteries.

Risk mitigation considerations thereafter could include providing operatives with certified full-face self-contained breathing apparatus, chemical-resistant boots among other protective equipment, as well as drench showers for post-response decontamination. Strategic positioning of fire-fighting equipment should also be a key consideration.

Early detection of such an incident can also be pivotal in managing the response, camera and thermal imaging could enable an expedient response. Such equipment might have already become commonplace for some modes, however conducting a thorough risk assessment for example when cargo is stored in warehouses would be prudent.

Consideration should also be given to the location of any incident that might include clean up and entry. The gases produced potentially leave toxic deposits on all surfaces and in the atmosphere. Therefore, once the incident is under control, potential hazards remain.